logo
Startseite ProdukteSauerstoff-Gas-Sensor

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Bescheinigung
CHINA ShenzhenYijiajie Electronic Co., Ltd. zertifizierungen
CHINA ShenzhenYijiajie Electronic Co., Ltd. zertifizierungen
Ich bin online Chat Jetzt

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices
YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Großes Bild :  YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Produktdetails:
Herkunftsort: Großbritannien
Markenname: YJJ
Modellnummer: O2-C2
Zahlung und Versand AGB:
Min Bestellmenge: 1
Preis: Verhandlungsfähig
Verpackung Informationen: Palettiert
Lieferzeit: 5-8 Tage
Zahlungsbedingungen: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Versorgungsmaterial-Fähigkeit: 2200

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

Beschreibung
Messbereich: 0 - 30% Sauerstoffkonzentration Stromabgabe: 80 bis 120 μA
Lastwiderstand: 47 - 100 Ohm Ansprechzeit: T90 (von 20,9% bis 0%) <45 Sekunden
Betriebstemperatur: -30 zu 55℃ Luftfeuchtigkeit: 5 - 95% RH
Druckbereich: 80 - 120 kPa Größe: 20,3 × 23 mm
Hervorheben:

electrochemical oxygen sensor 0-30% range

,

oxygen alarm device sensor

,

YJJ O2-C2 oxygen sensor

Product Description:

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices

 

Features:

Main parameters of the O2-C2 oxygen sensor are as follows:

Measurement range

0 - 30% oxygen concentration

Output signal

Current output: 80 - 120 μA (at 22℃, 20.9% oxygen)

Load resistance: 47 - 100 ohms

Response time

T90 (from 20.9% to 0%) < 45 seconds

Environmental adaptability

Operating temperature: -30 to 55℃

Humidity range: 5 - 95% RH

Pressure range: 80 - 120 kPa

Other features

Size: Φ20.3 × 23mm

Weight: < 18g

Storage period: 6 months (sealed preservation)

Linear error: ±0.6% of the full range

Application fields: Oxygen alarm device, atmosphere analyzer

 

Specifications:

Range 0 - 30 ppm
Sensitivity 1.9 ± 0.8 μA/ppm (at 20℃)
Baseline range -0.2 to 2.5 μA (@20℃)
Response time ≤ 45seconds (T90)

 

YJJ O2-C2 0-30% Electrochemical Oxygen Sensor Is Used In Oxygen Alarm Devices 0

Kontaktdaten
ShenzhenYijiajie Electronic Co., Ltd.

Ansprechpartner: Miss. Xu

Telefon: 86+13352990255