logo
Startseite ProdukteGas-Sensor

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Bescheinigung
CHINA ShenzhenYijiajie Electronic Co., Ltd. zertifizierungen
CHINA ShenzhenYijiajie Electronic Co., Ltd. zertifizierungen
Ich bin online Chat Jetzt

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting
SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Großes Bild :  SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Produktdetails:
Herkunftsort: Vereinigtes Königreich
Markenname: SGX
Modellnummer: SGX-4OX
Zahlung und Versand AGB:
Min Bestellmenge: 1
Preis: Verhandlungsfähig
Verpackung Informationen: Standardpaket
Lieferzeit: 3-5 Arbeitstage
Zahlungsbedingungen: L/C, D/A, D/P, T/T, Western Union, MoneyGram
Versorgungsmaterial-Fähigkeit: 3000 Prozent/Monate

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

Beschreibung
Reichweite: 0-25 % 02 Nullstrom (Offset): <0,6 % v/v O2
Ausgangssignal in einer Luft: 70 bis 130 μA Antwortzeit (T90): <15s
Hervorheben:

oxygen gas sensor through hole

,

portable oxygen gas detector

,

SGX-4OX gas sensor

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting

 

POISONING
SGX sensors are designed to operate in a wide range of harsh environments and conditions. However it is important that exposure to high concentrations of solvent vapours is avoided during storage, fitting into instruments and operation.When using sensors on
printed circuit boards(PCBs),degreasing agents should be used prior to the sensor being fitted.

 

ACID GASES
Acid gases such as CO,and SO, will be absorbed by the electrolyte and tends to increase the flux of oxygen to the electrode. This gives an enhanced oxygen signa of approximately 0.3% of signal per 1% CO.. The SGX 40X sensors are not suitable for continuous operation
in concentrations of CO, above 25%.

 

Specification:

Maximum Overload 30%  02
Long-term Output Drift  <5% per annum
Recommended Load Resistor  100 ohms
Warranty  2 years

 

SGX-4OX Oxygen Gas Sensors Portable Gas Detectors Through Hole Mounting 0

Kontaktdaten
ShenzhenYijiajie Electronic Co., Ltd.

Ansprechpartner: Xu

Telefon: 86+13352990255

Senden Sie Ihre Anfrage direkt an uns (0 / 3000)